In this case study, we present a project carried out in northern France for a manufacturer of taps and fittings. During the hot stamping process, the customer uses an oil containing graphite as a release agent, generating a complex pollutant composed of oil mist mixed with solid residues. A previous installation made by a competitor with inadequate technology was unable to handle this type of pollutant properly, causing serious filtration problems.
HF provided a tailor-made system designed to handle the specific pollutant. The solution includes a unit with a dual-stage pre-filtration, coalescence candle filters, and a final HEPA H13 filter, along with an external stack, a seasonal bypass for optimized airflow, and the HF Monitoring system for continuous delta P control. The four filtration stages are:
1°: Pre-filtration with metal mesh
2°: Pre-filtration with bag filters
3°: Filtration with coalescence candle filters
4°: Final filtration with HEPA H13 filter